Household gas meter test bench

Gas Meter Endurance Test Bench for G1.6-G4

This test bench is designed for endurance test of gas meter G1.6-G4 as IEC standard BS EN 1359-2017. Remove the meters under test from the exercise rig after 25 000, 150 000, 300 000 and 450000 cycles and determine their error of indication, using the same equipment as was used for the initial error of indication check. Cycle the meter for a nominal 16sec for randomly generated times within the following: Cycle A: --2/3 of Qmax for (5±1)s --1/3 of Qmax for (3±1)s Cycle B: --3/3 of Qmax for (5±1)s --0 flow for (3±1)s

Standards & Compliance

  • BS EN 1359-2017
  • GB/T6968-2011
  • JJF1354-2012

Technical Specifications

  • Main Specification:
  • 1. The flow points are Qmax, 2/3Qmax and 1/3Qmax.
  • 2. Testing pressure: +2.5Kpa~+4.0Kpa
  • 3. Tested meters: G1.6-G6
  • 4. Testing positions: 18pcs

Applications

Gas meter manufacturers / Metrology labs